Sixteen Channel Data Logger with Alarms
The complete solution for monitoring of temperature, humidity, pressure, CO2, voltage, current, pulses, events and other signals. Universal configurable inputs and outputs. For desktop use with rubber feet - see Optional accessories. For mounting to 19" rack - one rack unit 1U.
Data loggers are designed for measuring, recording, evaluation and subsequent processing of input electrical signals, which are subject to relatively slow changes (> 1s). In conjunction with the appropriate sensors and transducers are suitable for monitoring physical quantities.
The device includes traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO / IEC 17025. The calibration sheet is always loaded as modules.
If the defined required configuration of inputs by, calibration certificate proves calibration inputs according to the required configuration - more than one range for each of the 16 inputs.
Processing and analysis of measured data with connected Ethernet module:
- online in COMET Cloud
- COMET Database software
-
codeMS6R
-
Warranty3 years
-
In stock1 pcs
- 1 239.00 EUR
Technical data
Measured value
GENERAL TECHNICAL DATA
cyclic - after filling memory oldest data is overwritten by new
Parameters of configurable inputs
Features
Device enables:
- to measure and process 1 to 16 input signals
- to acquire autonomous time record of measured values
- create alarm states
- to perform other actions based on created alarms (audible, visual indication, controlling of relay outputs, sending SMS message, controlling of telephone dialer, sending of messages via several protocols of the Ethernet interface etc.)
- to monitor on-line measured values and states
- independent hysteresis setting, delay (for each channel separately)
- setting up to four alarm conditions (for each channel separately)
Common connectivity options:
Monitoring system MS may be configured for almost any desired measurement application. Sensors can be wired to datalogger in star-like connection as well as in serial. Combination of both is also possible. The monitoring system MS is characterized by a wide range of communication interfaces such as the RS232, RS485, USB, Ethernet and GSM or GPRS modem. Thanks to Wi-Fi routers several measuring systems MS can be wirelessly connected to a network.
Parameters and measuring ranges of configurable inputs MS6D
The monitoring systems MS6xx is equipped with 16 freely programmable universal inputs. Each of them can be set to the input signal according to the table below. The monitoring system is thus very flexible and offers ease of use. The RS485 input must be ordered separately if you want to use the Modbus or Advantech communication interface.
Main features:
- software configurable inputs for temperature sensors Pt and Ni, thermocouples and thermistors, voltage and current, two-state events, resistance, sensors with RS485 output
- memory for 500 000 records with automatic downloading to PC
- alarm indication via integrated siren, e-mail, SMS and two-state output to control other devices
- software for data analysis on PC
- communication interface USB, RS232, relays, RS485 (Modbus RTU), ETHERNET (Modbus TCP, SOAP, etc.)
Optional accessories and download
- Temperature probes Pt1000
- Thermocouple probes
- Probe extension cables
- Powering/Power supply
- Accredited calibration
- Communications and convertors
- Holders and fixings
- Monitoring software
- Relays module
- External display
- Version with higher protection
- Detectors
- Other accessories
- Solution for COMET presentation
- Software
- Others
- Manuals
- Catalogs
- Related products
Temperature probe Pt1000TG8/0, without connector
Temperature probe Pt1000TG8/0, without connector, cable 2 meters
Temperature probe Pt1000TG8/0, without connector, cable 5 meters
Temperature probe Pt1000TG8/0, without connector, cable 10 meters
Temperature probe 2061-250/0, without connector
Temperature probe 2061-250/0, without connector, cable 2 meters
Temperature probe 2061-250/0, without connector, cable 5 meters
Temperature probe 2061-250/0, without connector, cable 10 meters
Temperature probe Pt1000TG7/0, without connector
Temperature probe Pt1000TG7/0, without connector, cable 2 meters
Temperature probe Pt1000TG7/0, without connector, cable 5 meters
Temperature probe Pt1000TG7/0, without connector, cable 10 meters
Temperature probe 2304-220/0, without connector, cable 1 meter
Temperature probe 2021-150/0, without connector, cable 1 meter
Temperature probe PTS350A-2/0, without connector, cable 2 meters
Temperature probe 2034-220/0, without connector, cable 1 meter
Temperature probe 2061-200/0, without connector, cable 1 meter
Temperature probe 2061-200/0, without connector, cable 2 meters
Temperature probe 2061-200/0, without connector, cable 5 meters
Temperature probe 2061-200/0, without connector, cable 10 meters
Temperature probe PTS350A-5/0, without connector, cable 5 meters
Temperature probe PTS350A-10/0, without connector, cable 10 meters
Temperature probe Pt1000TGL40/0, without connector, cable 1 meter
Temperature probe Pt1000TGL40/0, without connector, cable 2 meters
Temperature probe Pt1000TGL40/0, without connector, cable 5 meters
Temperature probe Pt1000TGL40/0, without connector, cable 10 meters
Temperature probe Pt1000TR160/0, without connector, cable 1 meter
Temperature probe Pt1000TR160/0, without connector, cable 2 meters
Temperature probe Pt1000TR160/0, without connector, cable 5 meters
Temperature probe Pt1000TR160/0, without connector, cable 10 meters
Temperature probe Pt1000TR160/0, without connector, cable 15 meters
Temperature probe Pt1000TR160/0, without connector, cable 20 meters
PTS380K/0 temperature sensor with a stainless steel connection head and connector
Stick-in probe 2091-250/0, without connector, cable 1 meter
Stick-in probe 2091-250/0, without connector, cable 2 meters
Stick-in probe 2091-250/0, without connector, cable 5 meters
Stick-in probe 2091-250/0, without connector, cable 10 meters
Special probe 2071-80/0, without connector
Temperature probe Pt1000TG68/0, without connector, cable 2 meters
Temperature probe Pt1000TG68/0, without connector, cable 5 meters
Temperature probe Pt1000TG68/0, without connector, cable 10 meters
Temperature probe Pt1000TR125/0, without connector, cable 1 meter
Temperature probe Pt1000TR125/0, without connector, cable 2 meters
Temperature probe Pt1000TR125/0, without connector, cable 5 meters
Cryogenic temperature probe Pt1000TR125/0, without connector, cable 10 meters
Temperature probe Pt1000TR050S/0, without connector, cable 1 meter
Temperature probe Pt1000TR050S/0, without connector, cable 2 meters
Temperature probe Pt1000TR050S/0, without connector, cable 5 meters
Ultra thin temperature probe Pt1000TG3/0, without connector
Ultra thin temperature probe Pt1000TG3/0, without connector, cable 2 meters
Ultra thin temperature probe Pt1000TG3/0, without connector, cable 5 meters
Ultra thin temperature probe Pt1000TG3/0, without connector, cable 10 meters
Temperature probe Pt1000TR050S/0, without connector, cable 10 meters
Ambient temperature probe, 201-80/C
Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II
Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II, cable 2 meters
Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II, cable 5 meters
Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II, cable 10 meters
Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II, cable 15 meters
Temperature probe Pt1000TR050M/0, without connector, cable 1 meter
Temperature probe Pt1000TR050M/0, without connector, cable 2 meters
Temperature probe Pt1000TR050M/0, without connector, cable 5 meters
Temperature probe Pt1000TR050M/0, without connector, cable 10 meters
Thermocouple "K" surface probe, CP500
Thermocouple "K" stick-in probe, CZ550
Thermocouple "K" stick-in probe, CZ900
Thermocouple "K" wire probe, GD1250, without connector
Thermocouple "K" wire probe, GD1250, without connector, 2 meters
Thermocouple "K" wire probe, GD1250, without connector, 3 meters
Thermocouple "K" wire probe, GD1250, without connector, 4 meters
Thermocouple "K" wire probe, GD260, without connector
Thermocouple "K" wire probe, GD260, without connector, 2 meters
Thermocouple "K" wire probe, GD260, without connector, 3 meters
Thermocouple "K" wire probe, GD260, without connector, 4 meters
Thermocouple "K" wire probe, GD700, without connector
Thermocouple "K" wire probe, GD700, without connector, 2 meters
Thermocouple "K" wire probe, GD700, without connector, 3 meters
Thermocouple "K" wire probe, GD700, without connector, 4 meters
Thermocouple "K" insertion probe, GT1150
Extension cable thermocouple "K"
Extension cable thermocouple "K" female connector
Extension cable thermocouple "K", 2 meters
Extension cable thermocouple "K" female connector, 2 meters
Extension cable thermocouple "K", 3 meters
Extension cable thermocouple "K" female connector, 3 meters
Extension cable thermocouple "K", 4 meters
Extension cable thermocouple "K" female connector, 4 meters
Extension cable thermocouple "K", 5 meters
Extension cable thermocouple "K" female connector, 5 meters
Extension cable thermocouple "K", 6 meters
Extension cable thermocouple "K" female connector, 6 meters
Extension cable thermocouple "K", 7 meters
Extension cable thermocouple "K" female connector, 7 meters
Extension cable thermocouple "K", 8 meters
Extension cable thermocouple "K" female connector, 8 meters
Extension cable thermocouple "K", 9 meters
Extension cable thermocouple "K" female connector, 9 meters
Extension cable thermocouple "K", 10 meters
Extension cable thermocouple "K" female connector, 10 meters
Extension cable thermocouple "K", 11 meters
Extension cable thermocouple "K" female connector, 11 meters
Extension cable thermocouple "K", 12 meters
Extension cable thermocouple "K" female connector, 12 meters
Extension cable thermocouple "K", 13 meters
Extension cable thermocouple "K" female connector, 13 meters
Extension cable thermocouple "K", 14 meters
Extension cable thermocouple "K" female connector, 14 meters
Extension cable thermocouple "K", 15 meters
Extension cable thermocouple "K" female connector, 15 meters
Ac/dc adapter 21V/1A/25W unstabilized
AC/DC adapter 230Vac to 24Vdc/1A, switch-mode, EU
AC/DC adapter 230Vac to 24Vdc/1A, switch-mode, UK
AC/DC adapter 230Vac to 24Vdc/1A, switch-mode, US
Power supply 24Vdc for DIN 35mm rail
Uninterruptible power supply MIN-DC-UPS/24VDC/2
Uninterruptible power supply unit AWZ 224
Rechargeable battery module MINI-BAT/24DC/1,3AH
Rechargeable hermetic battery 12V/7,2Ah
Accredited calibration of 1-8 inputs of the MS Monitoring System
Accredited calibration of 1-16 inputs of the MS Monitoring System
KIT-GSM with modem GSM
Antenna for GSM modem
Communication cable for GSM modem
Communication cable for ext. terminal or output relays module 60cm
Communication cable for ext. terminal or output relays module 10m
Communication cable for ext. terminal or output relays module 5m
Converter RS232/485/422 to 10/100Base-TX with ac/dc adapter for MS
Four rubber feet for MS6R
Ethernet communication port (internal) for MS6R, MS6D
2G/4G RS232 modem - without accessories
Plug&Play LTE router for data communication between MS and COMET Cloud
Galvanically isolated input for MS data loggers for serial RS485 signal
Holders for output relays module mounting to DIN 35mm rail
DIN rail 35mm/226mm lenght with screws
DIN rail 35mm/226mm lenght with screws
COMET Database
COMET Cloud
COMET Cloud Lite for Android & iOS
Database Viewer for Comet Database
Software for COMET Monitoring Systems
Communication cable for ext. terminal or output relays module 60cm
Communication cable for ext. terminal or output relays module 10m
Communication cable for ext. terminal or output relays module 5m
Output relays module
Holders for output relays module mounting to DIN 35mm rail
DIN rail 35 mm for output relays module with screws
Terminal with display for MS55, MS6
Communication cable for ext. terminal or output relays module 60cm
Communication cable for ext. terminal or output relays module 10m
Communication cable for ext. terminal or output relays module 5m
External terminal for MS6x and MS55D dataloggers with housing and cable
Watertight case with wall holders for MS logger, no cutout in the lid
MS55D datalogger in IP54 protection case with connected terminal at the lid
Motion detector JS20
The LD-12 flood detector
Magnetic door contact SA-200-A
Magnetic door contact with cable length 10m
Magnetic door contact with cable length 15m
Magnetic door contact with cable length 2m
Magnetic door contact with cable length 20m
Magnetic door contact with cable length 30m
Magnetic door contact with cable length 5m
The optical smoke detector SD-283ST
Power detector SP008
External audio unit for MSxx and Multilogger
Screwdriver for WAGO terminals 3.5mm
COMET presentation case for samples
COMET Magnetic Foldable Stand
Software






Others

Manuals






Catalogs



Related products
COMET Database
Software for COMET Monitoring Systems
Ethernet Multilogger - universal datalogger with 4 inputs
Sixteen Channel Data Logger with Alarms
Sixteen Channel Data Logger for 19" Rack with Alarms
Sixteen Channel Data Logger with Alarms
Database Viewer for Comet Database
Reference
Monitoring of temperature and humidity of storage areas with food and veterinary preparations for dogs and cats
Type of application: Industry Building Management - HVAC
24/7 monitoring with MS6D
Type of application: Industry Building Management - HVAC
System of monitoring for IKEA Hungary
Type of application: Industry Building Management - HVAC
Restoring the original tempering hot-air heating system, Chateau Lednice
Type of application: Building Management - HVAC Culture
The Cairn of Peace Memorial
Type of application: Building Management - HVAC Culture
Cryogenic storage facility for SATVI
Type of application: Industry Healthcare and Laboratory
Blood Bank Upgrade
Type of application: Healthcare and Laboratory
CHIL Lab Cape Town
Type of application: Healthcare and Laboratory
Measurement of runoff wastewater treatment plant
Type of application: Healthcare and Laboratory Agriculture
CO2 sensors use in ventilation control
Type of application: SOHO (Small Office and Home Office) Building Management - HVAC Culture
HELUZ - great bricks for your house
Type of application: Industry Building Management - HVAC
Humidity monitoring in family houses
Type of application: Building Management - HVAC
Prague Castle
Type of application: Building Management - HVAC Server rooms and data centers Culture
Dr. Müller Pharma in Hradec Kralove, Drug Store
Type of application: Industry Healthcare and Laboratory
Masaryk University in Brno
Type of application: Industry Building Management - HVAC Weather monitoring
Drazice farm